Standard equipment
Starting system Electric starter 12-24 V, alternator 28 VDC/70 amp, belt driven
Fuel oil system Fuel main filter and pre-filter, electronic unit injection system
Lube oil system Lube oil filter
Combustion air system Set of dry-type airfilter with contamination indicator
Exhaust gas system Turbocharger outlet connection and mounting parts
Coolant system
Radiator-cooler with mechanically driven fan for engines with air charge air cooling, with
connecting parts for engine coolant circuit designed for 100% engine power, cooling air
pressure loss 200 Pa , 40°C/104°F ambient air temp.
Flywheel/housing Cast iron flywheel housing
Engine mounting Resilient
Optional equipment
Fuel oil system Electrical preheating unit
Flywheel/housing Flexplate for Allison transmission
Accessory drives One accessorie drive for front or rear mounts
Certification EPA, EU and MSHA/Canmet nonroad certification
A
0 von 0 Bewertungen
Durchschnittliche Bewertung von 0 von 5 Sternen
Bewerten Sie dieses Produkt!
Teilen Sie Ihre Erfahrungen mit anderen Kunden.
Anmelden
Keine Bewertungen gefunden. Teilen Sie Ihre Erfahrungen mit anderen.
Application Power definition
5A Continuous operation
w/100% load Load factor: ≥ 60 %, operating hours: unrestricted, overload: fuel stop (ICFN)
5B Continuous operation
w/variable load Load factor: < 60 %, operating hours: unrestricted, overload: fuel stop (ICFN)
Power output within 5% tolerance at standard conditions. Power definition according to ISO 3046 (ratings also correspond to SAE J 1995 and SAE J 1349 standard conditions)
Consult your distributor/dealer for the rating that will apply to your specific application.
Standard equipment
Starting system Electrical starter 24 V, alternator 28 V/80 A
Fuel system High pressure fuel injection with solenoid-valve controlled unit injection pumps and
multijet fuel injectors, fuel filter
Lube oil system Oil filter
Air system Turbo charging with charge-air cooling
Exhaust gas system Tree valves per cylinder
Coolant system Water-charge-air cooling
Flywheel/housing SAE 2
Engine mounting Resilient
Electronics and instrumentation Electronic engine management
Optional equipment
on request
Reference conditions:
> Intake-air temperature: 25°C (77°F)
> Ambient air pressure: 1000 mbar (14.5 psi)
> Altitude above sea level: 100 m (328 ft)
Subject to change without notice. Customization possible.
Engines illustrated in this document may feature options not fitted as standard.