4R 904C
Produktnummer:
SWD100005
Produktinformationen "4R 904C"
Application Power definition
5A Continuous operation
w/100% load Load factor: ≥ 60 %, operating hours: unrestricted, overload: fuel stop (ICFN)
5B Continuous operation
w/variable load Load factor: < 60 %, operating hours: unrestricted, overload: fuel stop (ICFN)
Power output within 5% tolerance at standard conditions. Power definition according to ISO 3046 (ratings also correspond to SAE J 1995 and SAE J 1349 standard conditions)
Consult your distributor/dealer for the rating that will apply to your specific application.
Standard equipment
Starting system Electrical starter 24 V, alternator 28 V/80 A
Fuel system High pressure fuel injection with solenoid-valve controlled unit injection pumps and
multijet fuel injectors, fuel filter
Lube oil system Oil filter
Air system Turbo charging with charge-air cooling
Exhaust gas system Tree valves per cylinder
Coolant system Water-charge-air cooling
Flywheel/housing SAE 2
Engine mounting Resilient
Electronics and instrumentation Electronic engine management
Optional equipment
on request
Reference conditions:
> Intake-air temperature: 25°C (77°F)
> Ambient air pressure: 1000 mbar (14.5 psi)
> Altitude above sea level: 100 m (328 ft)
Subject to change without notice. Customization possible.