6R 460C
Produktnummer:
SWD100001
Produktinformationen "6R 460C"
Application Power definition
5A Continuous operation
w/100% load Load factor: ≥ 60 %, operating hours: unrestricted, overload: fuel stop (ICFN)
5B Continuous operation
w/variable load Load factor: < 60 %, operating hours: unrestricted, overload: fuel stop (ICFN)
Power output within 5% tolerance at standard conditions. Power definition according to ISO 3046 (ratings also correspond to SAE J 1995 and SAE J 1349 standard conditions)
Consult your distributor/dealer for the rating that will apply to your specific application.
Rated power ICFN Peak torque Optimization
kW bhp rpm Nm lb-ft rpm
Application Medium duty operation (5B)
6R 460 C41 315 422 1800 2000 1475 1300 20, 23, 31*
6R 460 C51 335 449 1800 2000 1475 1300 20, 23, 31*
6R 460 C61 360 483 1800 2200 1623 1300 20, 23, 31*
6R 460 C71 375 503 1800 2200 1586 1300 20, 23, 31*
6R 460 C42 315 422 1800 2000 1475 1300 29, 38, 39
6R 460 C52 335 449 1800 2000 1475 1300 29, 38, 39
6R 460 C62 360 483 1800 2200 1620 1300 29, 38, 39
6R 460 C72 375 503 1800 2200 1620 1300 38, 39
Optimization: 20 EPA Nonroad T3 Comp (40CFR89)
23 EU Nonroad St IIIA Comp (97/68/EC)
29 China Onroad Stage V (GB17691-2005)
31 China NRMM Stage III (GB20981-2014)
38 EPA Nonroad T4i Comp (40CFR1039)
39 EU Nonroad St IIIB Comp (97/68/EC)
Standard equipment
Starting system Electrical starter 24 V, alternator 28 V/80 A
Fuel system High pressure fuel injection with solenoid-valve controlled unit injection pumps and
multijet fuel injectors, fuel filter
Lube oil system Oil filter
Air system Turbo charging with charge-air cooling
Exhaust gas system Four valves per cylinder
Coolant system Water-charge-air cooling
Flywheel/housing SAE 1
Engine mounting Resilient
Electronics and instrumentation Electronic engine management
SCR Aftertreatment System Engine (engines with
EPA Tier 4i/EU Stage 3B certification only)
Engine mounted SCR components with urea dosing unit, urea injection nozzle and heating
valve, vehicle mounted SCR components with SCR catalyst including muffler, urea supply
unit and SCR control unit
Optional equipment
on request
Reference conditions:
> Intake-air temperature: 25°C (77°F)
> Ambient air pressure: 1000 mbar (14.5 psi)
> Altitude above sea level: 100 m (328 ft)
Subject to change without notice. Customization possible.